Saumya, . and Dhingra, Renuka and Gupta, Anil and Karunanand, Busi (2017) Comparative Evaluation of Fracture Resistance and Microleakage of Reattached Anterior Tooth Fragment Using Two Different Flowable Composites- An in vitro Study. British Journal of Medicine and Medical Research, 21 (7). pp. 1-10. ISSN 22310614

[thumbnail of Saumya2172017BJMMR32526.pdf] Text
Saumya2172017BJMMR32526.pdf - Published Version

Download (252kB)

Abstract

Aim: To evaluate and compare the fracture resistance and microleakage of reattached anterior tooth fragment using two different flowable composites.

Study Design: In-vitro study.

Place and Duration of Study: The present in vitro study was carried out in the Department of Pedodontics and Preventive Dentistry, Faculty of Dental Sciences, SGT University, between June 2014 and July 2016.

Methodology: The subjects were selected from various sources. A total of 160 extracted permanent anteriors were selected for the study. Teeth were divided into 2 groups, 80 teeth in each group reattached with G-aenial Universal Flo and Esthet X-Flow, evaluated for fracture resistance testing using Universal testing machine. Half number of teeth tested for microleakage using Dye-penetration method. The results obtained from the study were then tabulated and statistically analyzed.

Results: Mean value for fracture resistance in Group I were observed (89.07 ± 32.46) whereas in Group II were observed (64.63 ± 40.33). On statistical analysis result found to be highly significant (p = 0.001). Out of 40 teeth, in Group I -16 observed no penetration whereas in Group II -10 teeth were observed no penetration. On Enamel-Dentin microleakage in Group I found to be in 6 teeth, whereas 14 teeth showed the same Enamel-Dentin penetration in Group II. But on statistical analysis, overall result found to be non-significant (p = 0.19).

Conclusion: Among the tested flowable composites, G-aenial Universal Flo showed highly significant fracture resistance than Esthet X-flow. Microleakage shows no significant differences between nanohybrid and microhybrid flowable composites.